⏱ Latency
~0.1–0.3 ms switch-to-PC on copper vs 3–20 ms on busy Wi-Fi. For gaming, calls and music production that gap is everything.
ETHERNET · TWISTED-PAIR · 1973 → TODAY
One cable. Four twisted pairs. Fifty years of “just plug it in and it’s 10 gigabits”. Scroll to pull the whole thing apart — 3D plugs, live physics, every CAT compared, and a termination lab that actually teaches your hands.
01 · WHY ETHERNET STILL WINS
Radio is shared, half-duplex airtime that your neighbours, microwave and fish-tank all fight over. A twisted pair is yours — full-duplex, deterministic, sub-millisecond, and it carries power too.
~0.1–0.3 ms switch-to-PC on copper vs 3–20 ms on busy Wi-Fi. For gaming, calls and music production that gap is everything.
A “1 Gbps” Wi-Fi link delivers ~300–500 Mbps real-world, shared. A Cat 6 run delivers 1,000 Mbps, all day, every device, simultaneously.
PoE++ pushes 90 W down the same pairs — cameras, APs, lighting, door entry. Try that over thin air.
02 · A BRIEF HISTORY OF GETTING FASTER
Xerox PARC memo. Coax, 2.94 Mbps, “Ether” as in luminiferous.
Thick coax “vampire taps”. 10 Mbps, 500 m segments.
Twisted-pair + star topology. The RJ45 era begins.
100 MHz cable, 100 Mbps. The office gets wired.
All 4 pairs, both directions, echo cancellation. Black magic.
10 Gbps over copper. PAM-16, LDPC, 500 MHz Cat 6A.
2 GHz, 30 m. Copper storms the datacenter top-of-rack.
802.3da automotive 10 Mbps single-pair; Cat 6A to every desk as standard.
03 · KNOW YOUR CATS
Live data from the Bun backend (GET /api/cables). Filter by what you actually need — 10-gig reach is the column that matters.
| Cable | Freq | Max speed | 10G reach | Shield | Cost | Pull it for… |
|---|
04 · ANATOMY OF A CABLE
Hover / tap a layer →
PVC for patch leads, LSZH for indoors, CMP plenum where air circulates, UV + gel-filled outside. The jacket is a fire, sunlight and crush rating — not decoration.
05 · WHY TWIST? (LIVE PHYSICS)
Each pair carries +V and −V (differential signalling). Interference adds the same spike to both wires — the receiver subtracts them and the spike vanishes. Twisting ensures both wires sample the same field on average; tighter twist = higher-frequency rejection.
06 · SHIELDING DECODER
Format is X/YTP — shield around all cables / shield around each pair. Click a code to see where it belongs.
Four naked twisted pairs in a jacket. Perfect for homes and clean offices. Cheapest, thinnest, easiest to terminate. Loses to motors, VFDs, fluorescent ballasts and 200-cable bundles — that's when you pay for foil.
07 · PICK THE RIGHT COPPER
Single thick conductor per wire. Holds a punch-down IDC blade gas-tight for decades, lower attenuation. Never flex it daily — it work-hardens and snaps.
90 m horizontalpunch-down keystones23 AWG
Dozens of hair-thin strands. Survives bending, coiling, chair wheels. Slightly lossier — that's why patch + equipment cords are capped at 10 m total.
flex-ratedcrimp plugs26–24 AWG
Drop-ceilings and ducts that carry air. Plenum jackets char and self-extinguish with low smoke. Code-mandated in air-handling spaces in most jurisdictions.
CMPLSZH indoors
Vertical shafts between floors. Flame-retardant so fire doesn't ride the shaft. Cheaper than plenum. Outdoors? UV + gel-filled or conduit — indoor jackets die in a summer.
CMRCMX outdoor
08 · 3D · THE RJ45 UNDER A MICROSCOPE
Procedural Three.js model — 8 gold contacts, 8 colour-coded conductors, clip and all. Hover pins to see which wire each one bites.
Pin 1 → White/Orange (T568B) — Transmit+ for 10/100, bidirectional for gigabit+.
09 · WIRING — A vs B, STRAIGHT vs CROSSOVER
Straight (same both ends): everything through a switch — 99% of life. Crossover (pairs 2↔3 swapped): like-to-like before Auto-MDIX — PC↔PC, switch↔switch, ancient uplink ports. Modern ports auto-sense, so crossover is now mostly trivia + exams.
A continuity tester can pass a split pair (e.g. pin 3 wired with the wrong white). It'll “work” at 10 Mbps and collapse at gigabit. Only a qualification/certification test catches it. Keep pairs together!
10 · TERMINATION LAB — DO IT LIKE A PRO
What you need: cable stripper, 110 punch-down tool, keystone jack, side cutters, tester. Optional but loved: cable comb, sharpie, velcro (never zip-ties on bundles).
Score the jacket only, flex and slide off. Nicked copper = future break. Keep twists intact.
Cut the plastic cross flush. Fan pairs out in order — no crossing over each other.
WO-O · WG-G · WB-B · WBr-Br across the jack's colour map. Double-check before seating.
Dress each wire into its IDC slot with twist preserved to < 13 mm from contact.
110 tool blade-out, one firm strike per wire. It seats and trims the tail.
Copper should be fully sunk, tails cut, no copper showing beyond the cap.
Snap the dust cap / wire holder, click jack into plate or panel.
A on one end + B on the other = accidental crossover. Label the run.
Wiremap first, length + PoE load next. Re-terminate any pair that isn't perfect.
11 · TESTING & TROUBLESHOOTING
A wiremap simulator. Inject a fault, then read the tester like it's 11 pm and the client demo is tomorrow.
Clean sweep. Ship it.
12 · POWER OVER ETHERNET
Heat is the enemy: keep PoE bundles ≤ 24 cables, prefer 23 AWG Cat 6A, and never bury bundles in insulation.
13 · CABLE PICKER — ASK THE BACKEND
14 · SIGNAL LAB — ATTENUATION
15 · PROVE IT — 8 QUESTIONS
Questions load from GET /api/quiz, scored by POST /api/quiz/score on the Bun backend.
16 · FIBRE — LIGHT IN GLASS
Fibre-optic cable guides laser light down a glass core by total internal reflection — no electrons, no crosstalk, no lightning surge, nothing to tap without cutting glass. Watch a ray ride the core:
Multimode (50 µm core) lets light take many paths. Rays arrive at different times — modal dispersion — which smears fast signals. That's why OM1 dies at 33 m of 10G.
Single-mode (9 µm core) allows exactly one path. Almost no dispersion, ~0.4 dB/km loss: 10 km on cheap optics, 100 km+ with the right lasers.
Fat 50–62.5 µm core, cheap 850 nm VCSEL transceivers, easy to connectorise. Reach: tens to hundreds of metres. The LAN/datacenter default inside buildings.
orange · aqua · lime jacketsLC duplex
Hair-thin 9 µm core, laser optics, pennies-per-metre cable. Reach: kilometres. Use it between buildings, across campus, and anywhere you might want 100G later without re-pulling.
yellow jacketfuture-proof
17 · FIBRE TYPES — OM vs OS
Live from the Bun backend (GET /api/fiber). Jacket colour is standardised — orange, aqua, lime, yellow — so you can identify glass from across the room.
| Fibre | Core | Light | 1G | 10G | 40/100G | Pull it for… |
|---|
18 · CONNECTORS + POLISH
Tiny 1.25 mm ceramic ferrule, duplex clip holds TX+RX as one. ~70% of new LAN/SAN installs. Uniboot reversed-polarity patch leads fix TX/RX swaps without re-terminating.
19 · TERMINATING GLASS — SPLICING LAB
Field-fitting individual connectors is a skill with a scrap bin. The sane paths: fusion-splice factory pigtails onto your pulled cable, use mechanical splices for one-offs, or skip all of it with a pre-terminated trunk + patch panels.
Remove jacket, aramid and 900 µm buffer with proper strippers. Glass cladding is 125 µm and scratches if you look at it wrong.
Lint-free wipe + >99% isopropyl, then a precision cleaver for a mirror-flat 90° end-face. A bad cleave = a bad splice, always.
Fusion splicer aligns cores and arcs them together (~0.05 dB loss). Slide the heat-shrink sleeve over first — everyone forgets once.
Shrink the sleeve, coil service slack in the splice tray (≥ 30 mm bend radius), label both ends.
Light-source + power meter (or OTDR for long runs) and keep the loss report. VFL red pen for continuity only — never for loss.
20 · LOSS BUDGET LAB
21 · GLOSSARY + FIELD NOTES
Lower = thicker. 23 AWG beats 24 AWG for PoE heat and attenuation. Cheap CCA (copper-clad aluminium) is banned from the standards — buy pure copper.
Near-End Crosstalk: a pair shouting into its neighbour. Alien (AXT): neighbouring cables shouting in. Cat 6A's thickness is mostly alien-crosstalk armour.
Permanent link = the in-wall 90 m. Channel = link + 10 m of patch cords. Certify the right one for the warranty.
Ports that detect straight vs crossover and adapt. Universal since gigabit — crossover cables are now exam trivia.
Keystones (punch-down) for solid in-wall cable. For plugs on solid: staggered or feed-through RJ45s — standard plugs are tuned for stranded.
Labour dwarfs cable cost. The second drop carries a phone, AP, HDMI extender or redundancy — for ~$5 of copper while the walls are open.
OS = Optical Single-mode (9 µm core, yellow, kilometres). OM = Optical Multimode (50 µm core, aqua/lime, hundreds of metres). Bigger OM number = more modal bandwidth, not a different size.
UPC (blue, flat) for datacom; APC (green, 8° angle) kills back-reflection for PON, RF video and long-haul. Never mate green to blue.
Logarithmic: 3 dB = half the light gone. A 0.5 dB dirty connector eats ~11% of your signal; two of them plus margin can sink an SR link.
…